Number of Units required when no pumping service is provided
50/50 Mix of Men & Women
One Unit provides approximately 200 uses with 4 hours between use
Average Hours at the Event |
||||||||||
Crowd Size |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
| 500 | 2 |
4 |
4 |
5 |
6 |
7 |
9 |
9 |
10 |
12 |
| 1,000 | 4 |
6 |
8 |
8 |
9 |
9 |
11 |
12 |
13 |
13 |
| 2,000 | 5 |
6 |
9 |
12 |
14 |
16 |
18 |
20 |
23 |
25 |
| 3,000 | 6 |
9 |
12 |
16 |
20 |
24 |
26 |
30 |
34 |
38 |
| 4,000 | 8 |
13 |
16 |
22 |
25 |
30 |
35 |
40 |
45 |
50 |
| 5,000 | 12 |
15 |
20 |
25 |
31 |
38 |
44 |
50 |
56 |
63 |
| 10,000 | 15 |
25 |
38 |
50 |
63 |
75 |
88 |
100 |
113 |
125 |
| 15,000 | 20 |
38 |
56 |
75 |
94 |
113 |
131 |
150 |
169 |
18 |
| 20,000 | 25 | 50 | 75 | 100 | 125 | 150 | 175 | 200 | 225 | 250 |
| 25,000 | 38 | 69 | 99 | 130 | 160 | 191 | 221 | 252 | 282 | 313 |
| 30,000 | 46 | 82 | 119 | 156 | 192 | 229 | 266 | 302 | 339 | 376 |
The length of time people spend at large public events is directly related to their plans to use portable sanitation facilities. People who plan to use portable sanitation facilities tend to stay longer. Their enjoyment of the event and expenditures therefore are affected by adequacy of portable sanitation facilities.